APC Rack Air Removal Fan Unit SX 100-240V 50/60HZ ACF402 for NetShelter 750mm Enclosure
The APC ACF402 APC Rack Air Removal Fan Unit is designed for performance heat removal for high-density equipment in NetShelter SX and VX enclosures.
The APC ACF402 Rack Air Removal Unit SX captures exhaust heat, returns the warm air to the plenum and eliminates hot spots from the data centre. Through automatic fan speed control based upon temperature, the fans will self-adjust for optimal performance. The APC ACF402 a unit-mounted LCD display, users can view temperatures at the rack, monitor alarm conditions and adjust unit set points. The integrated network management card allows for remote monitoring and control.
CONDITION
Brand New - A brand-new, unused, unopened, undamaged item in its original packaging.
WARRANTY
This item comes with 12 month manufacturer's warranty.
FEATURES
• Adjustable mounting frame: The frame can mount on Netshelter SX or VX enclosures and extends to accommodate 42U, 47U or 48U rack heights.
• Dual A-B Power Inputs: Draws power from the UPS for power protection with dual feeds for redundancy.
• Ducted Exhaust System: Removes hot air from the data center to prevent re-circulation and eliminate air mixing.
• Network interface: Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server.
• Fault-tolerant fan system: In the event of a fan failure, the remaining fan(s) will continue to operate.
• Field replaceable components: Fans and electronics module can be readily replaced without uninstalling the unit.
• Increased capacity: Higher rate of heat removal allows more equipment to be installed in each rack.
• LCD display: Alpha-Numeric Display which displays system parameters and alarms.
• Temperature monitoring: Changes in temperature are reported via the user interface or e-mail.
QUICK SPECIFICATIONS
• Product Description: APC rack fan kit
• Product Type: Rack fan kit
• Designed for: P/N: AP7950B, NBPD0160A, NBWL0355A, NBWL0356A, SMC15002U-BR, SMC1500I2U-BR, SMC1500I-2UC, SMT3000I2U-BR, SMX2000LVNCUS, SMX2000LVUS, SMX2200R2HVNC, SMX3000HV-BR, SMX3000HVTUS, SMX3000LV2U-BR, SMX3000LVUS, SRT1000RMXLA, SRT1000RMXLA-NC, SRT1000RMXLI, SRT1000RMXLI-NC, SRT1500RMXLA, SRT1500RMXLA-NC
WHAT'S INCLUDED
• APC Rack Air Removal Fan Unit SX 100-240V 50/60HZ ACF402
• Installation Guide
Do you have a question about this product? Please call 1800 90 90 99.
The APC ACF402 APC Rack Air Removal Fan Unit is designed for performance heat removal for high-density equipment in NetShelter SX and VX enclosures.